Category


Charging Pile Energy Management System Solution
Energy Consumption Monitoring Solution for Base Station
Wireless Temperature Monitoring System
Precision Distribution Monitoring Solution for IDC
Smart Motor Control and Protection Solution
Power Monitoring System
Cloud Platform for Power IOT
Smart Busway Monitoring Solution
Prepayment Cloud Platform
Operation And Maintenance Cloud Platform For Substations
Energy Management System
Energy Efficiency Management System
Medical Lsolation Power Supply System
Photovoltaic System Solutions
Smart Lighting Control System
Split Core Current Transformer
Hall Sensor Solution
Prepaid Solution
WHD Temperature & Humidity Controller Solution
Residual Current Operated Relay

Charging Pile Energy Management System Solution

Application



In recent years, in response to global warming and climate change caused by greenhouse gas emissions,major countries have focused on promoting electric vehicles to replace traditional fuel vehicles. And the construction of charging piles is very important in the promotion of new energy vehicles. Therefore, a large number of charging pile projects have emerged around the world.

 

Single phase and three phase AC, DC energy meters complies with the corresponding IEC standards and can be used in all kinds of AC and DC charging piles to realize charging energy measurement, and can transmit electrical parameters in real time through communication.

Structure



Main Functions



It can measure and display electrical parameters such as voltage, current, power, energy, and support RS485 communication and electric energy pulse output.

Monitoring electrical parameters such as voltage, current, power, frequency, harmonics and three-phase imbalance, cable and bus temperature.

 

1. Accuracy

Energy Accuracy: Class 0.5S or Class 1

 

2. Optional Configuration

Optional multi tariff.

 

3. Certificate

With CE or IEC certified.

Product Selection



● AC 220V

● 10(60)A

● RS485,MODBUS-RTU

● LCD display

● kWh Class 1,Kvarh Class 2

● U、I、P、Q、S、PF、kWh、kvarh

● DIN 35mm

● AC220V

● 10(60)A,20(100)A

● RS485(MODBUS-RTU)

● Set parameters

● LCD display

● kWh Class 1

● DIN 35 mm

●AC220V

●3×10(80)A

●RS485(MODBUS-RTU)

●Set parameters

●LCD display

●kWh Class 1

●DIN 35 mm

●AC220V

●3×1(6)A,3×10(80)A

●RS485(MODBUS-RTU)

●Set parameters

●LCD display

●kWh Class 0.5

●DIN 35 mm

● AC 3×220/380V,3×380V,3×57.7/100V,3×100V 

● 3×1(6)A,3×10(80)A

●  U、I、P、Q、S、PF、kWh、kvarh

● RS485(MODBUS-RTU)

● LCD display

● Frozen data 

● 2-31st  Harmonics

● kWh Class 0.5S,kVarh Class 2 

●Measure voltage, current, power, forward and reverse power in DC system

●Local display

●RS485(MODBUS-RTU)

●Set parameters

●DI/DO, Relay alarm output

●Applications:DC panels, solar power, telecommunications base stations, and charging posts

●RS485 communication interface

●Supports Modbus-RTU protocol

●Relay alarm output and digital input function

●Set the ratio, alarm, and communication through the meter panel keys according to different requirements

●Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power

Measurement

AC, DC, pulse and other complex current

 

 

9) AFL-T Shunt

Measurement

Common Specification: 300A/75mV