Menu
|
Major Scenario
|
|
|
Solution Structure
|
|
|
Your Benefit
|
|
All System Management Acrel-2000MG could manage and control all common power systems and loads like grids power, diesel generator, EV charger, winds power, solar PV, ESS and common loads. |
Peak-Valley Arbitrage By using the energy management and control plan of Acrel-2000MG, we could realize peak shaving &valley filling energy usage strategy for peak-valley arbitrage. Benefit of peak-valley arbitrage could be check in Acrel-2000MG energy magament system.
|
Power Demand Control Acrel-2000MG could set a power demand threshold and manage all the power system in micro-grids so that the overall loads power demand won't exceed this limitation value. No extra fine happend due to exceeding the power demand. |
Back-up Power Source Acrel-2000MG EMS system could set the plan for back-up power source to prevent the influence of unpredicatable power outage. |
|
Software Overview
|
|
System Homepage Homepage include a general view of site actual micro-grids power system situation. Energy consumption situation, carbon dioxide emisstion info, profit gain from control plan and new energy, weather station infor, power curve and etc. |
Profit Analysis Analysis about how much profit gained from peal-valley arbitrage strategy, new energy power generation profit and etc.
|
Visualized Operation Providing topology according to actual site situation. Real-time data and status for you to realize a simple and visualized maintanence. |
Solar PV Monitoring General monitoring for solar PV system including solar PV power generation and profit gained by it. Weather station infomation, voltage¤t&power curve and etc.Grid-connected power quality monitoring and analysis |
Wind Power Monitoring General monitoring for wind power system including wind power generation and profit gained by it. Weather station infomation, voltage¤t&power curve and etc.Grid-connected power quality monitoring and analysis. |
ESS Monitoring General monitoring for ESS energy storage system including charging&discharging power, energy, status information. Also, the SOC cruve, PCS&BMS status could be all checked in Acrel-2000MG. Also, the opeartion mode could be changed between peak-valley mode, scheduled curve, demand control, etc |
EV Charger Monitoring General monitoring for EV charger including charging energy, profit gain by EV charger. Also, the detail working status, voltage, current, charging amount of each EV charger could be checked. |
Power Quality Analysing Continuously monitor the power quality and reliability status of power system, including steady-state data such as voltage harmonics, voltage flicker, and voltage imbalance, as well as transient data like voltage sags/swells, voltage interruptions, and transient voltage data. Perform monitoring, analysis, and waveform recording of these parameters, and also monitor transient voltage and current events. |
Optimized Power Control Acrel-2000MG could set various control plan to realize optimized power operation for saving your money and make profit. Such as peak-valley arbitrage, max demand control and etc |
|
Hardware Overview
|
|
Product Picture | Name&Model | Technical Description |
ANET Seires IoT Gateway |
The ANET series IoT gateway utilizes an embedded hardware computing platform and features multiple downstream communication interfaces and multiple upstream network interfaces. It is designed to aggregate and organize communication data from all intelligent monitoring/protection devices within a target area and upload it in real-time to the master station system. This setup completes the functions of remote signaling and remote measurement for energy data collection. |
|
ADL3000-E Series 3-phase DIN-rail Multi-function Energy Meter |
The ADL3000-E is an intelligent electric meter specifically designed for power supply systems, industrial and mining enterprises, and utility companies. It is used to calculate electricity consumption and manage electrical demand. Key features include high accuracy, compact size, and easy installation. The device integrates measurement of all electrical parameters and comprehensive power metering management, providing data for the past 12 months. It can check the content of up to 31 harmonics and total harmonic distortion. Remote communication and control are enabled through digital inputs and relay outputs, and it also features alarm outputs. The ADL3000-E is suitable for various control systems, SCADA systems, and energy management systems. All instruments comply with the relevant technical requirements of IEC62053-21 and IEC62053-22 standards for power meters. | |
APView500 Seires Power Quality Analyser |
Utilizing a high-performance multi-core platform and an embedded operating system, it adheres to the measurement methods for power quality indicators specified in IEC61000-4-30 and follows the IEC61000-4-15 standard. The system integrates functions such as harmonic analysis, waveform sampling, voltage sag/swell/interruption monitoring, flicker monitoring, voltage imbalance monitoring, event recording, and measurement control into one unit. | |
AM5SE Series Medium-voltage Protection Relay |
The AM5SE series microcomputer protection and control devices integrate protection, control, measurement, communication, and monitoring functions into one unit. They feature rich resources, comprehensive configuration, easy maintenance, and stable performance, making them suitable for protection and control of power systems with voltage levels of 35kV and below. These devices provide protection for incoming lines, main transformers, distribution transformers, motors, capacitors, bus couplers, and PTs. The application areas include power, water conservancy, transportation, petroleum, chemical, coal, metallurgy, and new energy industries. |
|
Get Started
|
|
|
Step 1: Confirm Request Contact us for discussing about your request and some technical specs so that we can customize a solution and select the most compatible products for you. |
|
Step 2: Get Quotation Get a quotation from us and valuate your cost and benefits. We have freight forwarder for world wide shipment and support 1 MOQ. |
|
Step 3: Sample Order Test Order small quantity of our products for testing, we will assist you with full technical support for both installation and adjustment remotely. |
|
Step 4: Mass Production Once the products worked normally as your request, it’s time for processing mass order and production to fulfill your total request. |
|
Major Scenario
|
Solution Structure
|
Your Benefit |
All System Management
Acrel-2000MG could manage and control all common power systems and loads like grids power, diesel generator, EV charger, winds power, solar PV, ESS and common loads.
|
Peak-Valley Arbitrage
By using the energy management and control plan of Acrel-2000MG, we could realize peak shaving &valley filling energy usage strategy for peak-valley arbitrage. Benefit of peak-valley arbitrage could be check in Acrel-2000MG energy magament system.
|
Power Demand Control
Acrel-2000MG could set a power demand threshold and manage all the power system in micro-grids so that the overall loads power demand won't exceed this limitation value. No extra fine happend due to exceeding the power demand.
|
Back-up Power Source
Acrel-2000MG EMS system could set the plan for back-up power source to prevent the influence of unpredicatable power outage.
|
System Overview
|
System Homepage
Homepage include a general view of site actual micro-grids power system situation. Energy consumption situation, carbon dioxide emisstion info, profit gain from control plan and new energy, weather station infor, power curve and etc.
|
Profit Analysis
Analysis about how much profit gained from peal-valley arbitrage strategy, new energy power generation profit and etc.
|
Visualized Operation
Providing topology according to actual site situation. Real-time data and status for you to realize a simple and visualized maintanence.
|
Solar PV Monitoring
General monitoring for solar PV system including solar PV power generation and profit gained by it. Weather station infomation, voltage¤t&power curve and etc.Grid-connected power quality monitoring and analysis
|
Wind Power Monitoring
General monitoring for wind power system including wind power generation and profit gained by it. Weather station infomation, voltage¤t&power curve and etc.Grid-connected power quality monitoring and analysis.
|
ESS Monitoring
General monitoring for ESS energy storage system including charging&discharging power, energy, status information. Also, the SOC cruve, PCS&BMS status could be all checked in Acrel-2000MG. Also, the opeartion mode could be changed between peak-valley mode, scheduled curve, demand control, etc
|
EV Charger Monitoring
General monitoring for EV charger including charging energy, profit gain by EV charger. Also, the detail working status, voltage, current, charging amount of each EV charger could be checked.
|
Power Quality Analysing
Continuously monitor the power quality and reliability status of power system, including steady-state data such as voltage harmonics, voltage flicker, and voltage imbalance, as well as transient data like voltage sags/swells, voltage interruptions, and transient voltage data. Perform monitoring, analysis, and waveform recording of these parameters, and also monitor transient voltage and current events.
|
Optimized Power Control
Acrel-2000MG could set various control plan to realize optimized power operation for saving your money and make profit. Such as peak-valley arbitrage, max demand control and etc
|
Your Benefit |
Product |
Technical Description |
ANET Seires IoT Gateway |
The ANET series IoT gateway utilizes an embedded hardware computing platform and features multiple downstream communication interfaces and multiple upstream network interfaces. It is designed to aggregate and organize communication data from all intelligent monitoring/protection devices within a target area and upload it in real-time to the master station system. This setup completes the functions of remote signaling and remote measurement for energy data collection. |
ADL3000-E Series 3-phase DIN-rail Multi-function Energy Meter |
The ADL3000-E is an intelligent electric meter specifically designed for power supply systems, industrial and mining enterprises, and utility companies. It is used to calculate electricity consumption and manage electrical demand. Key features include high accuracy, compact size, and easy installation. The device integrates measurement of all electrical parameters and comprehensive power metering management, providing data for the past 12 months. It can check the content of up to 31 harmonics and total harmonic distortion. Remote communication and control are enabled through digital inputs and relay outputs, and it also features alarm outputs. The ADL3000-E is suitable for various control systems, SCADA systems, and energy management systems. All instruments comply with the relevant technical requirements of IEC62053-21 and IEC62053-22 standards for power meters. |
APView500 Seires Power Quality Analyser |
Utilizing a high-performance multi-core platform and an embedded operating system, it adheres to the measurement methods for power quality indicators specified in IEC61000-4-30 and follows the IEC61000-4-15 standard. The system integrates functions such as harmonic analysis, waveform sampling, voltage sag/swell/interruption monitoring, flicker monitoring, voltage imbalance monitoring, event recording, and measurement control into one unit. |
AM5SE Series Memium Voltage Protection Relay |
The AM5SE series microcomputer protection and control devices integrate protection, control, measurement, communication, and monitoring functions into one unit. They feature rich resources, comprehensive configuration, easy maintenance, and stable performance, making them suitable for protection and control of power systems with voltage levels of 35kV and below. These devices provide protection for incoming lines, main transformers, distribution transformers, motors, capacitors, bus couplers, and PTs. The application areas include power, water conservancy, transportation, petroleum, chemical, coal, metallurgy, and new energy industries. |
Get Started
|
Step 1: Confirm Request
Contact us for discussing about your request and some technical specs so that we can customize a solution and select the most compatible products for you.
|
Step 2: Get Quotation
Get a quotation from us and valuate your cost and benefits. We have freight forwarder for world wide shipment and support 1 MOQ.
|
Step 3: Sample Order Test
Order small quantity of our products for testing, we will assist you with full technical support for both installation and adjustment remotely.
|
Step 4: Mass Production
Once the products worked normally as your request, it’s time for processing mass order and production to fulfill your total request.
|